Scotsman Drain Pump Assembly 230V/50Hz (part number 620471-00, also written 62047100 or 620471/00) is a genuine OEM drain (or “water pump” / “vacuum pump” in some listings) assembly for certain Scotsman commercial ice machines, particularly the Easy-Fit / EC-series cube ice makers designed for 230 V / 50 Hz power (common in Europe, UK, Australia, South Africa, and other 50 Hz markets).
Key Specifications
- Manufacturer: Scotsman Industries
- Part number: 620471-00 (OEM)
- Description: Drain Pump Assembly 230V/50Hz
- Voltage / Frequency: 230 V, 50 Hz
- Power: Approximately 100 W (cross-referenced as GRE type CL.F pump)
- Inlet / Outlet: Inlet ≈ Ø 20 mm, outlet ≈ Ø 11 mm
- Length: ≈ 140 mm
- Rotation: Right-hand (clockwise when viewed from the appropriate end)
- Approximate dimensions / weight: Roughly 11–16 cm × 12–14 cm × 7.5 cm; weight ≈ 1.35 kg
- NSN (National Stock Number): 4320-01-631-5822 (listed as a liquid-operated / drain pump)
It is typically a sealed centrifugal-style pump used in the pump-out water drain (PWD) system. In these machines, meltwater and overflow collect in a sealed reservoir; level sensors trigger the pump to evacuate water (often for ~8 seconds per cycle). The pump can lift water up to about 1.5 m vertically or push it up to ~30 m horizontally, making it suitable for installations without a convenient gravity drain.
Compatible Models
This pump is widely listed for Scotsman Easy-Fit and related EC/EF series machines, including:
- EC45, EC55, EC85, EC105, EC125, EC175, EC225
- EC46, EC56, EC86, EC106, EC126, EC176, EC206, EC226
- EF103, EF124, EF156, EF206
It also appears in parts lists for EC046 and related units (as the 230/50 water pump assembly). Some later or revised models use superseding numbers such as 62047102R or 62047104R (often marked as water pumps for newer variants). Always verify against the specific model, serial number, and parts diagram of your machine, as Scotsman has produced many similar EC-series units with evolving drain systems.
In Scotsman EC-series ice makers with a drain pump (as opposed to pure gravity-drain versions), the assembly sits in the water-drain system, usually at the base. It works with a sealed sump/reservoir, level-sensing pins or probes, check valve, hoses, and often a control board that activates the pump when the water level rises. Common reasons for replacement include failure to pump, continuous running, short-cycling, leakage, or sludge/build-up that prevents proper evacuation—symptoms that can lead to standing water in the bin, reduced ice production, or error conditions.
Related maintenance typically involves cleaning the drain hose, sump, and check valve (using warm soapy water and a mild bleach solution for sanitizing), as scale, slime, or debris is a frequent cause of pump issues. Always disconnect power and water before servicing.
Notes and Considerations
- Confirm voltage/frequency match (230 V / 50 Hz). A 60 Hz or different-voltage pump will not be correct.
- Check the machine’s parts diagram or service manual for the exact position (often item 0001 in the water-drain system section) and any associated gaskets, brackets, tubes, or level pins that may also need attention.
- There are related but distinct Scotsman drain-pump kits and higher-capacity or residential versions (different part numbers).
- Installation usually involves mounting the assembly, connecting inlet/outlet hoses and electrical leads, and ensuring the check valve is correctly oriented. Professional installation is advisable for commercial units to maintain hygiene and warranty.